PRODUCT CATALOG
ASC IHB P Series
Design Features
- Horizontally mounted design
- Self cleaning by using backflush principle created by reverse flow
- Standard sizes from 2” – 24”. Larger sizes available upon request.
- Available In flanged end connections.
- Standard thru bolt cover design. Other covers on request
- Perforated screens are standard.
- All welders are qualified to ASME Section IX.
- Strainers designed to meet the requirements of ASME Section VIII,Div.1.
- Drain with plug is is standard . Drain valves can be supplied on request
- Vents with plug and Dp indicators are standard
- Large body with Guaranteed low pressure drop as per Table 3in engineering data .
- Net free straining area minimum 6 times for standard screen
- DP Switch are standard. Transmitters can be supplied on request
- Electrically actuated butterfly backflush valve are standard. Other valves and Pneumatic valves on request
- Robust bearing design
- Backflush primemover -3 Phase AC motor 230 volts standard for sizes higher that 25 nb single phase AC motor 230v standard for 25b and lower.
- Gear box to reduce sppeds to 7 to 14 rpm
Material Data
| Body | IS1239,3589 ASTM A106, SS304/316, DUPLEX STEEL |
| Cover | A105, SA 516 GR 70, CS TO IS 2062, SS316,304, DUPLEX STEEL |
| Fastners | A193 B7 Bolts & A 194 2 H Nuts with |
| With spring washer. SS 304/316 | |
| Gaskets | CAF, NACF, Neoprene, NItrile,PTFE |
| Drain / Vent Plug | A105, CS TO IS 1875-II, Stainless Steel |
| Filter Element | SS 304,316, Duplex, Brass, Monel, Hastalloy C |
* Other materials available on request.
Standard Screens
| Size Range | Opening |
|---|---|
| 2″-8″( 50mm-200mm) | 0.125 IN. (3.2mm) |
| 10″-12″(250mm-300mm) | 0.125 IN. (3.2mm) |
| 14″-24″(250mm-600mm) | 0.188 in. (4.8mm) |
Control Panel Specs
| IP 65 Double door panel is standard | Data Capture |
| Panel Size : 400 x 400 x300mm | Cleaning cycle – Period run |
| Power supply : 230 Volts 3 phase AC | Valve failure report |
| 3 modes viz., Manual,Built in auto and Remote -with 3 point selector swith as standard | Olr activated report |
| Adjustable field setable, Periodic and cyclic timer | Debris overload through Dp switch report |
| Valve Feed Back-Open, close and error | Indications |
| Overload protection for Backflush Motor is standard | Power On |
| RS 485 output for remote data Collection | Filteration ON |
| LCD Display | Filter choked |
| Drain Valve open |
Dimensions

| Size mm |
A mm |
B mm |
C mm |
|---|---|---|---|
| 50 | 350 | 430 | 1735 |
| 80 | 620 | 430 | 2040 |
| 100 | 620 | 510 | 2040 |
| 150 | 620 | 600 | 2330 |
| 200 | 620 | 600 | 2330 |