Design Features

  • IN Line Vertically mounted design
  • Self cleaning by using backflush priciple created by reverse flow
  • Standard sizes from 2” – 24”. Larger sizes available upon request.
  • Available In flanged or Butt-weld end connections.
  • Perforated screens are standard.
  • May be installed in horizontal pipelines.
  • All welders are qualified to ASME Section IX.
  • Strainers designed to meet the requirements of ASME Section VIII,Div.1.
  • Drain with plug is standard . Drain valves can be supplied on request
  • Vent with plug is standard
  • Large body with Guaranteed low pressure drop as per Table 3 . in engineering data .
  • Net free straining area minimum 6 times for standard screen
  • DP Switches are standard. Transmitters can be supplied on request
  • Electrically actuated butterfly backflush valve are standard. Other valves and Pneumatic valves on request
  • Robust bearing design
  • Backflush primemover -3 Phase AC motor 230 volts standard
  • Gear box to reduce sppeds to 7 to 14 rpm

Material Data

Body IS1239,3589 ASTM A106, SS304/316, DUPLEX STEEL
Cover A105, SA 516 GR 70, CS TO IS 2062, SS316,304, DUPLEX STEEL
Fastners A193 B7 Bolts & A 194 2 H Nuts with
With spring washer. SS 304/316
Gaskets CAF, NACF, Neoprene, NItrile,PTFE
Drain / Vent Plug A105, CS TO IS 1875-II, Stainless Steel
Filter Element SS 304,316, Duplex, Brass, Monel, Hastalloy C

* Other materials available on request.

Standard Screens

Size Range Opening
2″-8″( 50mm-200mm) 3 mm
10″-12″(250mm-300mm) 3 mm
14″-24″(250mm-600mm) 5 mm

Control Panel Specs

IP 65 Double door panel is standard Data Capture
Panel Size : 400 x 400 x300mm Cleaning cycle – Period run
Power supply : 230 Volts 3 phase AC Valve failure report
3 modes viz., Manual,Built in auto and Remote -with 3 point selector swith as standard Olr activated report
Adjustable field setable, Periodic and cyclic timer Debris overload through Dp switch report
Valve Feed Back-Open, close and error Indications
Overload protection for Backflush Motor is standard Power On
RS 485 output for remote data Collection Filteration ON
LCD Display Filter choked
Drain Valve open

Dimensions

Size
in-mm
A
mm
B
mm
C
mm
D
mm
2″ – 50 375 110 365 300
3″ – 80 535 145 370 300
4″ – 100 579 175 400 300
6″ – 150 1141 215 450 300
8″ – 200 1313 250 500 300
10″ – 250 1507 285 675 300
12″ – 300 1766 315 750 300
14″ – 350 1538 375 900 300
16″ – 400 1992 400 1000 300
20″ – 500 2091 435 1125 300
24″ – 600 3444 500 1250 300